The Levoit Humidifier Dual 100 is a compact, dual-mist ultrasonic humidifier designed for small to medium rooms. It features a 1.5L water tank, adjustable mist output (low/high), 360° nozzle, optional night light, auto shut-off when empty, and quiet operation. Ideal for improving air quality and relieving dryness. Below are key sections for safety, features, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation & Setup 3. First-Time Use 4. Specifications 5. Controls and Settings 6. Operation Modes 7. Cleaning & Maintenance 8. Safety Features 9. Care & Storage 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Water Tank, Base Unit, Mist Nozzle, Control Panel, Power Adapter.

FeatureDescription
Dual Mist OutputAdjustable low/high mist settings for customized humidity
1.5L Water TankProvides up to 10 hours of continuous operation on low setting
360° NozzleRotatable for directing mist in any direction
Optional Night LightSoft blue light that can be turned on/off
Auto Shut-OffAutomatically turns off when water tank is empty
Quiet Ultrasonic TechnologyOperates quietly, suitable for bedrooms and offices
Control PanelTouch buttons for power, mist level, and night light
Removable Water TankEasy to fill and clean
Compact DesignSpace-saving footprint for desks or nightstands
Power AdapterDC 24V input for safe operation

Installation & Setup

Unpack and inspect contents. Place on a flat, stable, and dry surface.

  1. Remove all packaging materials from the humidifier and accessories.
  2. Separate the water tank from the base unit by lifting the tank straight up.
  3. Fill the tank with cool, clean tap or distilled water up to the MAX fill line. Do not overfill.
  4. Reattach the tank to the base, ensuring it is seated properly and securely.
  5. Plug the power adapter into the DC input on the base, then plug the adapter into a standard 120V AC wall outlet.

WARNING! Place humidifier on a level, water-resistant surface away from electronics and direct sunlight. Do not use on carpet.

First-Time Use

Power on the humidifier; follow these steps for initial operation.

  1. Ensure the humidifier is properly assembled and plugged in.
  2. Press the POWER button on the control panel. The indicator light will illuminate.
  3. Select mist output: Press the MIST button to toggle between LOW (steady light) and HIGH (brighter light) settings.
  4. Adjust nozzle: Rotate the 360° nozzle to direct mist away from walls, furniture, and electronics.
  5. Optional: Press the NIGHT LIGHT button to turn the soft blue light on or off.

CAUTION! Use clean, cool water only. Do not add essential oils, fragrances, or chemicals directly into the water tank, as this may damage the unit.

Specifications

Controls and Settings

Access all functions via the touch control panel on the front of the base unit.

Control Panel: POWER Button (On/Off), MIST Button (Cycle Low/High), NIGHT LIGHT Button (On/Off).

Indicator Lights: Power (Blue), Mist Level (Blue - Low, Brighter Blue - High), Night Light (Blue when on).

Manual Adjustments: Mist output level, Nozzle direction, Night light on/off.

Automatic Features: Auto shut-off when water tank is empty.

Operation Modes

Two primary mist output settings for different needs.

  1. Low Mist Mode: For maintaining gentle humidity overnight or in small spaces. Provides quieter operation and longer run time.
  2. High Mist Mode: For quickly raising humidity levels in drier conditions or medium rooms. Provides stronger mist output.
  3. Night Light Mode: Optional soft blue light provides a gentle glow for nighttime use without being disruptive.

Tip: For best results, keep doors and windows closed in the room where the humidifier is operating.

Cleaning & Maintenance

Regular cleaning is essential for performance and to prevent mold or bacteria growth.

  1. Daily: Empty and refill the water tank with fresh water if not used completely.
  2. Weekly Cleaning:
    • Unplug the unit and separate the tank from the base.
    • Empty any remaining water.
    • Clean the tank and base with a soft cloth and a mixture of white vinegar and water (1:1 ratio). Do not submerge the base in water.
    • Gently wipe the ultrasonic mist transducer (metal disc inside base) with a vinegar-dampened cloth to remove mineral deposits.
    • Rinse all parts thoroughly with clean water and air dry completely before reassembly.
  3. Descaling: If using hard water, descale more frequently (every 1-2 weeks) using the vinegar solution.

WARNING! Never use abrasive cleaners, detergents, or chemicals. Never immerse the base unit in water.

Safety Features

Auto Shut-Off: Activates when the water tank is empty, preventing the unit from running dry and overheating. Tip-Over Protection: The unit will stop misting if tilted or knocked over.

Care & Storage

Unplug and empty all water before cleaning or storing. Clean thoroughly as per weekly instructions and allow all parts to dry completely before reassembly or storage. Store in a cool, dry place in its original box if possible.

CAUTION! Do not store with water in the tank. Do not expose to extreme temperatures.

Regulatory Information

FCC Compliance: This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. Copyright © Levoit. For support, visit www.levoit.com or contact customer service at 1-888-726-8520.

Troubleshooting

SymptomPossible CauseCorrective Action
No mist outputEmpty tank / Incorrect assemblyFill tank with water. Ensure tank is properly seated on base.
Low mist outputMineral buildup / Low mist settingClean transducer and tank. Select High mist setting.
Water leakageTank not sealed / OverfilledCheck tank seal and alignment. Do not fill above MAX line.
Unit not powering onNo power / Loose connectionCheck wall outlet and power adapter connection. Ensure unit is plugged in.
Unusual noiseVibration / Debris in waterPlace on a level surface. Use clean, filtered water.
White dust around unitMinerals in hard waterUse distilled or demineralized water. Clean the unit more frequently.

Reset: Unplug the unit for 5 minutes, then plug back in.

Service: 1-888-726-8520; www.levoit.com